DIRECT IGNITION TROUBLESHOOTING
With proper installation and maintenance, your new Gas Fireplace will provide years of
SYMPTOM | CHECK | ACTION |
No spark when system is turned to “ON” | Check for 120V between black “hot” line | If 120V not present, check fuse or circuit |
and reset cycle* has been completed. | at control module and “white” return at | breaker or repair wiring leading to |
| module. | fireplace. |
Spark for six (6) seconds at ignitor, but no | a. Check that gas is turned on and system | Turn gas on and/or purge system. |
ignition of burner. | purged. |
|
| b. Check that tips of ignitor are directly | Position electrodes so tips are directly |
| above ports on main burner. Spark is | above burner port ports and about ¼" to |
| between electrodes and not from one | 3/8" above burner. |
| electrode to burner. |
|
| c. Check for 120V at each coil on the gas | If 120V present, but gas valve does not |
| valve and listen for click, indicating gas | click, replace gas valve. |
| valve is opening. |
|
Spark for six (6) seconds, main burner | Check for clean ground path between | Clean, position according to wiring diagram, |
lights, but goes out when spark stops. | electrode bracket and fireplace chassis. | and repair defective electric connections. If |
| Check wiring to wiring diagram label. | all electrical connections are clean and |
| Check for broken electrode on | correct, replace module. |
| lead attachment to module. |
|
Main burner lights normally and then goes | a. Check ignitor to burner gap. | Igniter should be located 1/4" to 3/8" above |
out. |
| burner area. |
| b. Check | Replace spark electrode assembly. |
| for shorts. |
|
| c. Refer to installation instructions | Repair as required. |
| troubleshooting guide for issues such |
|
| as venting. |
|
DIRECT IGNITION PROPANE/LP GAS CONVERSION
The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CSA B149.2 installation code (Canada) and with the requirements of the National Fuel Gas Code Z223.1/NFPA 54 (United States).
WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in this instruction is not followed exactly, a fire, explosion, or production of carbon monoxide may result causing property damage, personal injury, or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer's instructions supplied with the kit.
Installer notice: Using an ink pen, fill out the required information on the conversion label. Remove the backing from label and stick label in a visible position on bottom of fireplace close to gas valve.
Installer notice: These instructions must be left with the appliance.
Instructions for converting your direct ignition fireplace from natural gas to propane/LP gas.
All direct ignition fireplaces are shipped from the factory equipped to operate on natural gas. To convert the direct ignition fireplace to operate on propane/LP gas, follow the instructions on Page
26.Please see the appropriate parts list for your model for parts included with the direct ignition fireplace.
Check the items in the kit with the parts list. Notify the supplier of any items that are missing before installing the conversion kit.