Vulcan-Hart BVD36FP52(F,L)N-1, BVP42FP52(F,L)N-1 Gas Supply Cont, Checking Manifold Pressures

Models: BVD34FP30(F,L)N-1 BVD36FP32(F,L)N-1 BVD36FP52(F,L)N-1 BVP42FP32(F,L)N-1 BVD34FP50(F,L)N-1 BVP42FP52(F,L)N-1

1 40
Download 40 pages 38.56 Kb
Page 9
Image 9
GAS SUPPLY (CONT)

GAS SUPPLY (CONT)

Checking Manifold Pressures

Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold pressure of approximately 3.5" w.c. (.871kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 4.5" w.c. (1.120kPa) for the purpose of input adjustment to a maximum of 14.0" w.c. (3.484kPa). Propane gas models will have a manifold pressure approximately 10.0" w.c. (2.49kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 10.8" w.c. (2.68kPa) for the purpose of input adjustment to a maximum of 14.0" w.c. (3.484kPa).

BURNER ASSEMBLY

PIEZO

IGNITER

SLIDING

VALVE ACCESS

COVER

Figure 8

GAS LINE HOLE

3 ½”

FROM FRONT OF

APPLIANCE TO

GAS LINE HOLE

BVD34 SERIES - 10”

BVD,P (36,42) - 13 ½”

Figure 7

REAR TAB (BURNER BASE)

LOCATIONS

FLEXIBLE GAS CONNECTOR

GAS SUPPLY LINE

FIREBOX BOTTOM

CUTOUT ACCESS

19400-3-0406

Page 9