C24EO SERIES STEAMER - ELECTRICAL OPERATION

ELECTRICAL OPERATION

COMPONENT FUNCTION

Buzzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Creates audible signal when timed cook cycle is complete and when a low water condition exists.

Limiting Contactor (1CON) . . . . . . . . . . . . . . . Supplies line voltage to heating element assembly. Energized whenever Power Switch (1S) is on and High Limit Thermostat (1TAS) and Low Water Thermostat (2TAS) are closed.

Regulating Contactor (2CON) . . . . . . . . . . . . . Supplies line voltage to heating element assembly. Energized whenever Hold Thermostat (3TAS) is closed or the temperature controller calls for heat.

Heating Element . . . . . . . . . . . . . . . . . . . . . . . . Located below water reservoir. Heats water to produce steam. Fuses (1FU & 2FU) . . . . . . . . . . . . . . . . . . . . . . Protect control circuitry from over-currents.

Low Water Light (1LT) . . . . . . . . . . . . . . . . . . . Amber (AM) colored light. Lit when Low Water Thermostat (2TAS) senses water level is too low inside steamer.

On Light (2LT) . . . . . . . . . . . . . . . . . . . . . . . . .

Amber (AM) colored light. Lit when Power Switch (1S) is on.

Cook Light (3LT) . . . . . . . . . . . . . . . . . . . . . . .

Red (RD) colored light. Lit when High Limit (1TAS) and Low

 

Water (2TAS) thermostats are closed, door is closed and timer

 

is set.

Relay (K1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Controls Regulating Contactor (2CON) based on input from Hold Thermostat (3TAS) and Temperature Controller. Does not allow Timer Motor to run while Hold Thermostat (3TAS) is closed.

Relay (K2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Latches Power Switch (1S) circuit. Turns on Low Water Light (1LT) and Buzzer when steamer is low on water.

Relay (K3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Controlled by Power Switch (1S). Keeps Buzzer from sounding and Low Water Light (1LT) off when switch is in off position.

Power Switch (1S) . . . . . . . . . . . . . . . . . . . . . . Rocker switch that turns steamer OFF and ON (momentary on). Switch also resets Low Water Light (1LT) and Buzzer.

Door Switch (1SW) . . . . . . . . . . . . . . . . . . . . .

Removes power from a portion of the steamer control circuit

 

when door is opened.

High Limit Thermostat (1TAS) . . . . . . . . . . . . . Protects steamer by removing control circuit power if the heating element assembly temperature goes above 495EF.

Low Water Thermostat (2TAS) . . . . . . . . . . . .

Monitors presence of water inside steamer.

Hold Thermostat (3TAS) . . . . . . . . . . . . . . . . .

Controls temperature of cavity for pre-heat/hold mode (opens at

 

175E F). Disables timer countdown if cavity temperature is too

 

low.

Timer Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Counts cook time of product when time is dialed. Energizes

 

buzzer and de-energizes temperature controller when time

 

expires.

Temperature Control . . . . . . . . . . . . . . . . . . . .

Monitors temperature probe and cycles power to regulating

 

contactor (2CON) for steam generation.

Temperature Probe . . . . . . . . . . . . . . . . . . . . .

Senses cooking compartment temperature at steam vent and

 

sends a corresponding DC voltage back to the temperature

 

control (J-type thermocouple).

Transformer (1T) . . . . . . . . . . . . . . . . . . . . . . .

Steps down line voltage to 120VAC control circuit voltage.

F25386 (June 2010)

 

Page 16 of 24