C24EO SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS
2.Disconnect lead wires to component being replaced.
3.Remove component.
4.Reverse procedure to install replacement component and check steamer for proper operation.
NOTE: If replacing temperature control, see TEMPERATURE CONTROL CALIBRATION in
SERVICE PROCEDURES AND ADJUSTMENTS.
TIMER
1.Remove right SIDE PANEL.
2.Disconnect lead wires to timer.
3. Remove timer knob.
4.Remove rotary shaft seal from timer shaft and remove timer.
5.Reverse procedure to install and check steamer for proper operation.
HOLD THERMOSTAT
1.Remove right SIDE PANEL.
2.Remove lead wires and mounting nuts.
3.Remove hold thermostat.
4.Apply a small amount of thermal transfer compound to the mating surface (disk side) of the replacement thermostat.
A.Spread the compound completely and evenly over the surface of the thermostat.
5.Reverse procedure to install and check steamer for proper operation.
F25386 (June 2010) |
| Page 6 of 24 |
|