C24EO SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS
5.Partially remove heating element assembly by pulling assembly towards you.
6.Remove high limit thermostat bulb and bracket.
7.Remove heating element assembly.
Installation
NOTE: When replacing element assembly for 3 pan unit with 240V supply, disconnect and insulate element leads with orange, green, and red markers (three 664W elements not used).
1.Completely and evenly coat heating element assembly with thermal transfer compound using notched trowel. (Use one 13.5 oz. tube of thermal transfer compound)
2.Partially install heating element assembly, then mount high limit thermostat bulb and bracket to assembly.
A.Apply thermal transfer compound between high limit bulb and heating element assembly.
3.Install heating element assembly. Push element assembly towards front of machine.
4.Connect lead wires to 1CON and 2CON in noted positions.
5.Check steamer for proper operation.
MANUAL DRAIN VALVE
1.Remove right SIDE PANEL and REAR PANEL.
2.Remove pin and washer to disconnect the handle linkage from linkage bracket.
3. Remove nut and linkage bracket.
4.Remove drain valve.
5.Reassemble parts removed in reverse order of removal.
A.Apply pipe thread sealant to plumbing threads before assembly.
6.Check steamer for leaks and proper operation.
Page 9 of 24 |
| F25386 (June 2010) |
|