C24EO SERIES STEAMER - TROUBLESHOOTING
TROUBLESHOOTING
SYMPTOM |
| POSSIBLE CAUSES |
Compartment leaks water around door. | 1. | Steamer not level. |
| 2. | Steamer overfilled. |
Steam leaks around door. | 1. | Worn gasket. |
| 2. | Damaged gasket. |
| 3. | Steam vent pipe blocked. |
| 4. | Door not adjusted. |
Steamer will not heat (cook light off, low | 1. | Line voltage incorrect or transformer malfunction. |
water light off). | 2. | Control circuit fuse(s) open. |
| 3. | High limit thermostat open. |
| 4. | Door open or door switch malfunction. |
| 5. | Power switch off or inoperative. |
| 6. | Relay K3 malfunction. |
| 7. | Timer malfunction or timer off (timed mode only). |
Steamer will not heat (cook light on, low | 1. | Line voltage incorrect. |
water light off). | 2. | Heating element malfunction. |
| 3. | Regulating contactor malfunction. |
| 4. | Relay K1 malfunction. |
| 5. | Temperature probe malfunction. |
| 6. | Temperature controller malfunction. |
Timer motor does not run. | 1. | Door open or door switch malfunction. |
| 2. | High limit thermostat open. |
| 3. | Low water thermostat open. |
| 4. | Timer inoperative. |
Door not closing properly. | 1. | Door latch assembly. |
| 2. | Striker adjustment. |
Door won’t open. | 1. | Latch inoperative. |
Buzzer not operating. | 1. | Timer malfunction. |
| 2. | Buzzer malfunction. |
Water spraying out of steam vent pipe | 1. | Temperature control set point too high. |
during a cook cycle. | 2. | Temperature probe malfunction. |
| 3. | Temperature control malfunction. |
High water usage. | 1. | Temperature control set point too high. |
| 2. | Temperature probe malfunction. |
| 3. | Temperature control malfunction. |
| 4. | Steamer operating in constant mode. |
Excessive or inconsistent cook times. | 1. | Door left open between loads. |
| 2. | Temperature control set point too low. |
| 3. | Heating element malfunction. |
|
|
|
F25386 (June 2010) | Printed in U.S.A. |