RANGES MOUNTED ON CASTERS
Ranges mounted on casters must use a exible connector (not supplied by manufacturer) that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 • CSA 6.16 and a
If disconnection of the restraint is necessary, turn o the gas supply before disconnection. Reconnect this restraint prior to turning the gas supply on and returning the range to its installation position.
CONNECT GAS LINE STRAIN
RELIEF HERE
Fig. 1
Separate instructions for installing casters to the range are included with the casters.
Note: If the range is installed on casters and is moved for any reason, it is recommended that the range be releveled front to back and side to side.
LEVELING
Curb Installation
Ranges must overhang curb 3" (76 mm) in front. To level each range, remove oven bottom. Adjust four corner leveling bolts as required to level the appliance on all sides.
Convection Oven
Remove lower front kick plate. Remove two screws holding electric gas valve and move valve o to the side. Pull oven burner out of compartment through opening. Adjust four corner bolts to level range. Replace burner valve and kick plate.
Floor Installation on Legs
The 6" (152 mm) adjustable legs must be tightened securely. Level each range by turning the foot portion of the adjustable legs.
Lining up Range Battery
In batteries of ranges, it is recommended that the center range be installed and leveled rst. Level each range, one at a time, to line up high shelf and roll front with adjacent range. Bolt the high shelves and roll fronts together.