INSTALLING OVERLAPPING GRIDDLE TOP

1.Bolt ranges together and level per instructions in this manual.

2.Remove chrome bull noses from ranges receiving overlapping griddle tops. Bull noses are held by bolts on the bottom side.

3.MANUAL CONTROLS ONLY — Set griddle tops in place and level with bolts located under the griddle top in both rear corners. Should you desire griddle plate to slope forward, adjust accordingly. Make sure hole in front gutter fits into cast iron drain in range. Reinstall bull noses.

4.THERMOSTAT CONTROL ONLY — Set griddle top in place and support front with 4" to 6" (10 cm to 15 cm) blocks. Insert thermostat probe into smaller of two angles on bottom of griddle top (bend probe slightly while inserting to hold in place). Slide insulation sleeving around probe lead up to angle on griddle top. Coil excess lead near thermostat, leaving as little as possible in burner area. Make sure that thermostat probe lead is not over burner or pilot flame. Remove supporting blocks and lower griddle top in place.

Level griddle top with bolts located under both rear corners. Should you desire griddle plate to slope forward, adjust accordingly. Make sure hole in front gutter fits into cast iron drain in range. Reinstall bull noses.

Leveling bolts are provided under each griddle plate at the rear, should you desire griddle plate to slope forward. Top frame sealing channels are supplied to seal off any space between two or more ranges.

GAS CONNECTIONS

CAUTION: All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases.

This appliance must be connected with a gas supply line as large or larger ID (net inside diameter) than the gas pipe inlet provided on the rear of the appliance. Connect gas supply to the range(s). Make sure the pipes are clean and free of obstructions, dirt, and piping compound.

Codes require that a gas shutoff valve be installed in the gas line ahead of the range(s).

Ranges manufactured for use with propane gas are equipped with fixed orifices.

A gas pressure regulator must be furnished by the installer or plumber at the time of installation. The regulator must be listed by a nationally recognized testing agency. These appliances are rated at the following pressure: Natural Gas - 5" W.C. (Water Column) (1.25 kPa); Propane Gas - 10" W.C. (2.49 kPa).

WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.

After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.

TESTING THE GAS SUPPLY SYSTEM

When test pressures exceed 1/2 psig (3.45 kPa), the range and its individual shutoff valve must be disconnected from the gas supply piping system.

When test pressures are 1/2 psig (3.45 kPa) or less, the range must be isolated from the gas supply system by closing its individual manual shutoff valve.

12

Page 12
Image 12
Vulcan-Hart ML-44905Z operation manual Installing Overlapping Griddle TOP, GAS Connections, Testing the GAS Supply System

ML-44905Z specifications

The Vulcan-Hart ML-44905Z is a state-of-the-art commercial microwave designed for efficiency, reliability, and convenience in busy kitchen environments. Known for its robust construction and innovative features, this model stands out as an essential tool for foodservice operations such as restaurants, catering services, and delis.

One of the main features of the Vulcan-Hart ML-44905Z is its spacious interior, which accommodates a wide range of food items. With a generous cooking cavity, it allows for multiple dishes to be heated or cooked simultaneously, significantly reducing wait times during peak service hours. This efficiency is essential in fast-paced settings where speed and performance are crucial.

The microwave utilizes advanced technology to deliver consistent cooking results. Its precise timing and power levels ensure that food is heated evenly, minimizing the risk of cold spots. The unit typically features programmable settings that allow chefs to store and recall specific cooking times and power levels for different dishes. This not only streamlines operations but also helps maintain consistent food quality, an essential aspect of customer satisfaction.

Safety is another paramount consideration in the design of the Vulcan-Hart ML-44905Z. The unit incorporates multiple safety features, including a safety interlock system that prevents the microwave from operating when the door is open. This feature protects users from potential hazards while ensuring compliance with industry safety standards.

Durability is a defining characteristic of the Vulcan-Hart ML-44905Z. Constructed from high-quality stainless steel, it is built to withstand the rigors of daily use in commercial kitchens. The material not only adds to the unit's longevity but also makes it easy to clean, maintaining a hygienic environment.

In addition to its impressive performance features, the Vulcan-Hart ML-44905Z is also designed with energy efficiency in mind. This model employs energy-saving technologies that contribute to lower operating costs, making it an economically sound investment for any foodservice establishment.

Overall, the Vulcan-Hart ML-44905Z delivers a blend of functionality, safety, and efficiency, making it a trusted choice for culinary professionals. Its combination of versatile features and robust design not only meets the demands of a bustling kitchen but also enhances the overall cooking experience. This microwave represents the cutting edge of cooking technology, bringing speed and precision to food preparation.