LOCATION
CAUTION: The equipment area must be kept free and clear of combustible substances.
The minimum installation clearances from combustible and noncombustible construction for ranges using inputs of 30,000 Btu/Hr per open top burner are:
| Combustible | Noncombustible | |
Sides | 20" | (51 cm) | 0" |
Rear | 2" | (5 cm) | 0" |
The minimum installation clearances from combustible and noncombustible construction for ranges using inputs of 20,000 Btu/Hr per open top burner are:
| Combustible | Noncombustible |
Sides | 6" (15 cm) | 0" |
Rear | 2" (5 cm) | 0" |
The ranges are suitable for installation on combustible floors when 6" (15 cm) adustable legs are used. When legs are removed, use only on noncombustible floors, curb, or platform, with front appliance projecting 3" (8 cm) beyond curb or platform.
Ranges with Snorkle ovens should be installed on 6" (15 cm) legs or casters, allowing 6" (15 cm) clearance from the rear of the range. If ranges with Snorkle ovens are installed directly on curbs, without legs, or in
All modular ranges are to be installed only on
The installation location must allow adequate clearances for servicing and proper operation. A minimum front clearance of 35" (88 cm) is required.
The range(s) must be installed so that the flow of combustion and ventilation air will not be obstructed. Adequate clearance for air openings into the combustion chamber(s) must be provided. Make sure there is an adequate supply of air in the room to allow for combustion of the gas at the burners.
INSTALLATION CODES AND STANDARDS
Your Vulcan range(s) must be installed in accordance with:
In the United States:
1.State and local codes.
2.National Fuel Gas Code, ANSI/Z223.1 (latest edition), available from American Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA 22209.
3.National Electrical Code
— 9 —