ELECTRICAL DATA CHARTS

VR RANGES WITH STANDARD OVENS OR VS RANGES WITH CABINET BODY

"N/A" RANGES NOT AVAILABLE 480 VOLT

 

 

3 PHASE LOAD

 

 

NOMINAL AMPS PER LINE WIRE

 

 

 

 

 

TOTAL

KW PER PHASE

 

 

 

 

3 PHASE

 

 

 

 

 

1 PHASE

 

KW

208V

240V

480V

 

208V

 

 

 

240V

 

 

480V

 

208V

240V

480V

MODEL

CONN.

X-Y

Y-Z

X-Z

X

Y

Z

X

 

Y

 

Z

X

Y

 

Z

XYZ

XYZ

XYZ

VR1,2,5

21.7

7.7

5

9

70

53

58

60

 

46

 

51

30

23

 

25

104

90

45

VR1,2,5 / VB73

27.7

10.7

8

82

78

71

71

 

68

 

61

 

133

115

VS,VM1,2,5

15

5

5

5

42

42

42

36

 

36

 

36

18

18

 

18

72

63

31

VS,VM1,2,5 / VB73

21

8

8

54

67

54

47

 

58

 

47

 

101

88

VR3,6,7

20.7

7.7

5

8

65

53

54

57

 

46

 

47

28

23

 

24

99

86

43

VR3,6,7 / VB73

26.7

10.7

8

78

78

67

68

 

68

 

58

 

128

111

VS,VM3,6,7

14

5

5

4

38

42

38

33

 

36

 

33

16

18

 

16

67

58

29

VS,VM3,6,7 / VB73

20

8

8

50

67

50

43

 

58

 

43

 

96

83

VR4

18.7

6.7

4

8

61

45

50

53

 

39

 

43

19

27

 

22

90

78

39

VR4 / VB73

24.7

9.7

7

8

74

70

63

64

 

60

 

54

27

30

 

33

119

103

N/A

VS,VM4

12

4

4

4

33

33

33

29

 

29

 

29

14

14

 

14

58

50

25

VS,VM4 / VB73

18

7

7

46

58

46

40

 

51

 

40

 

87

75

480 Volt Only:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VR1,2,5 / VB73

21.7

7.7

11

9

 

 

30

34

 

36

N/A

VR3,6,7 / VB73

26.7

7.7

11

8

 

 

28

34

 

34

N/A

VS,VM1,2,5 / VB73

21

5

11

5

 

 

18

29

 

29

44

VS,VM3,6,7 / VB73

20

5

11

4

 

 

16

29

 

27

42

VR4 / VB73

24.7

6.7

10

8

 

 

27

30

 

33

N/A

VS,VM4 / VB73

18

4

10

4

 

 

14

25

 

25

38

VR RANGES WITH CONVECTION OVENS

 

 

3 PHASE LOAD

 

NOMINAL AMPS PER LINE WIRE

 

 

 

 

TOTAL

KW PER PHASE

 

 

 

 

3 PHASE

 

 

 

 

1 PHASE

 

KW

208V,240V & 480V

 

208V

 

 

 

240V

 

 

480V

 

208V

240V

MODEL

CONN.

X-Y

Y-Z

X-Z

X

Y

Z

X

 

Y

 

Z

X

Y

Z

XYZ

XYZ

VR1C,2C,5C

22

6.2

6.2

9.6

66

51

66

57

 

45

 

57

29

22

29

106

92

VR1C,2C,5C/VB73

28

9.2

9.2

9.6

78

76

78

68

 

66

 

68

34

33

34

135

117

VR3C,6C,7C

21

6.2

6.2

8.6

62

51

62

54

 

45

 

54

27

22

27

101

87

VR3C,6C,7C/VB73

27

9.2

9.2

8.6

74

76

74

64

 

66

 

64

32

33

32

130

112

VR4C

19

5.2

5.2

8.6

58

43

58

50

 

37

 

50

25

19

25

91

79

VR4C/VB73

25

8.2

8.2

8.6

70

68

70

61

 

59

 

61

30

29

30

120

104

VEX AND VMX RANGES

 

 

3 PHASE LOAD

 

NOMINAL AMPS PER LINE WIRE

 

 

 

 

 

TOTAL

KW PER PHASE

 

 

 

 

3 PHASE

 

 

 

 

1 PHASE

 

KW

208V

240V

480V

 

208V

 

 

 

240V

 

 

480V

 

208V

240V

480V

MODEL

CONN.

X-Y

Y-Z

X-Z

X

Y

Z

X

 

Y

 

Z

X

Y

Z

XYZ

XYZ

XYZ

VEX,VMX1

5

2.5

2.5

11

21

11

9

 

18

 

9

4.5

9.0

4.5

24

21

10.4

VEX2,VMX2

5

24

21

10.4

VEX3,VMX3

4

2

2

8

17

8

7

 

14

 

7

3.6

7.2

3.6

19

17

8.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"VB73" in above charts denotes an electric elevated broiler installed over the range.

9

Page 9
Image 9
Vulcan-Hart VRC, VS operation manual VR Ranges with Convection Ovens, VEX and VMX Ranges