series 9 DecodingComputer System

Volume and Input

The volume can be controlled between 0 and 100. Each increment of 1 on the display is 0.5 dB, so the attenuation range is from -50 dB at a volume setting of zero, to 0 dB at volume setting of 100. The display jumps to the main screen whenever the volume or input is changed.

Mute

Mute is engaged by pressing the mute key on the remote control. The volume is set to zero by sending a stream of zero data to the output, or by interrupting the output. When entering or leaving mute mode, the volume ramps up or down such that it takes roughly 2 seconds to get from a volume of 100 to volume 0. Pressing mute or volume up (but not volume down) disengages mute. Pressing Mute displays the main screen as shown:

 

 

 

 

 

Le

v el :95

(mut

e)

cal

IN

2 : G l ass

O pti

 

No Data

If there is no digital signal present on the selected input, the display indicates this by flashing the name of the input alternately with the words “NO DATA”:

 

 

Le

v el :95

IN

2 : N o Da t a