INSTALLATION
RIGID PIPE VENTING -
HORIZONTAL TERMINATIONS
The shaded area in the diagram below shows all allowable combinations of vertical runs with horizontal terminations. Maximum one 90O elbow
(two 45o elbows equal one 90o elbow) using
Residential and Manufactured Homes /
Mobile Homes Installations
The venting arrangements diagrammed below, have a minimum of 75% (flue loss) efficiency with Fan Off, as required for manufactured homes. (Actual efficiency may be as high as 85%.)
RIGID PIPE VENTING - VERTICAL TERMINATIONS
for both Residential & Manufactured Homes/Mobile Homes
The shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs with vertical terminations. Maximum two 45o elbows (not including the 45o elbow attached to the unit.). All vertical and offset to vertical vent installations require Vent Restrictor #1. If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a
Straight Vertical Terminations
Offset to Vertical Terminations
Vent Restrictor must be set at 5/8" for this venting installation.
18 | Waterford TARA T25 Direct Vent Freestanding Gas Stove |