INSTALLATION
HORIZONTAL
INSTALLATIONS
1)Set the unit in its desired location. Check to determine if wall studs are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit.
2)Assemble the desired combination of pipe and elbow to the appliance adapter with pipe seams oriented down. Offset the pipe seams as double seams in one place will cause the outer pipe to take an oval shape.
Kit comes complete with 18" of straight vent
-
3)With the pipe attached to the stove, slide the stove into its correct location, and mark the wall for a
*Dia 2a & 2b: As speci- fied in CGA B149 Instal- lation Code. Local codes or regulations may re- quire different clearanc- es.
Diagram 3
Diagram 2a
Diagram 1
Note:
a)The horizontal run of vent should have a 1/ 4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temper- atures and may present the possibility of a fire.
b)The location of the horizontal vent termina- tion on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. For External Vent Terminal Locations, see diagram on page 9.
c)Snorkel Terminations:
For installations requiring a vertical rise on the exterior of the building,
Diagram 2b
NOTE: For Snorkel terminations in ABOVE grade installations, follow national or local code requirements.
Below Grade Snorkel Installation
If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to pre- vent water from entering the Snorkel Ter- mination. Refer to
4)Install wall penetration heat shield in the center of the
5)If installing termination on a siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding. Dia. 3.
6)Take the Riser Vent terminal and separate the Backing Plate from the Riser Vent Front by removing 8 screws as shown in dia- gram 4.
Diagram 4
7)Install the Backing Plate into the wall pene- tration heat shield and attach using 4 screws. Dia. 4.
8)Connect all pipe sections to unit and install into wall:
a)Measure pipe length required and cut to length. Hint: use the cut end of the
b)Push the pipe sections completely together, the minimum pipe overlap is
Hint: Apply sealant to female end.