EXTERIOR VENT TERMINAL

10

Waterford TARA T25 Direct Vent Freestanding Gas Stove

 

 

 

EXTERIOR VENT TERMINAL

A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm)

H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally from

LOCATIONS

 

B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm)

 

the centerline of the regulator.

 

C= Clearance to permanently closed window *(min. 12"/30cm)

J=

Clearance to service regulator vent outlet *(min. 36"/90cm)

 

D= Vertical clearance to ventilated soffit located above the terminal within a horizontal

K= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to

 

distance of (24"/60cm) from the centerline of the terminal (min. 18"/46cm) check with

 

any other appliance *(12"/30cm) #(9"/23cm)

 

local code.

L=

Clearance to a mechanical air supply inlet *(min. 72"/1.8m)

 

E= Clearance to unventilated soffit (min. 12"/30cm)

 

#3' (91cm) above if within 10' (3m) horizontally.

 

F= Clearance to outside corner: with AstroCap Termination Cap (min. 6"/15cm), with

M= **Clearance above paved sidewalk or a paved driveway located on public property

 

Dura-Vent Termination Cap (14"/36cm)

 

*(min. 84"/2.1m)

 

G= Clearance to inside corner: withAstroCapTermination Cap (min. 6"/15cm), with Dura-

N= Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)***

 

Vent Termination Cap (12"/30cm)

 

 

 

Note: * As specified in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances.

**A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. #In accordance with the current ANSI Z223.1 / NFPA 54, National Fuel Gas Code.