Waterford Appliances T25-LP Optional Fan Installation, Locating Your Gas Stove, TARA Clearances

Models: T25-LP T25-NG

1 36
Download 36 pages 19.32 Kb
Page 7
Image 7
TARA Clearances

INSTALLATION

Use the minimum clearances shown in the diagrams below:

TARA Clearances

 

Side Wall to Unit*

A

6"

/

150 mm

Back Wall to Unit

B

3"

/

75 mm

Unit Corner to Wall

C

2"

/

50 mm

Unit to Alcove Ceiling

 

13" /

330 mm

Max. Alcove Depth

 

24" /

610 mm

*If installing the side shelves, which are 6" wide, additional space is required.

Minimum ceiling height is 47"/1294mm from floor.

A)Cross Corner

B)Room Divider

C)Island

D)Flat on Wall

E)Flat on Wall Corner

F)Flush with Wall/Alcove

3)Remove the Top Control Panel Assembly by removing the three screws.

Top Control Panel Assembly

4)

Remove the nylon hole plug from the control

 

panel.

5)

Install the fan speed controller onto the

 

control panel and secure with nut and

 

washer. Connect the red and black wires

OPTIONAL FAN

INSTALLATION

for units starting with serial #

11106 to 13347 / 217000001 to present.

Fan Kit Contains:

Qty. Description

1Fan Assembly c/w green wire attached

1Thermodisc

1power cord

22-1/4" x 20 hex nut

1)Remove the thermodisc from the bracket on the fan assembly, do not disconnect the wires.

from the wire harness to speed controller.

NOTE: Speed control wires must be in the

down position when control panel is in

place.

Fan Speed

Controller

LOCATING YOUR

GAS STOVE

When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper opera- tion.

For Vent Termination requirements, see page 10.

Thermodisc

2)Remove the rear access panel on the back of the stove by removing the 6 screws. Take care not to cut wires when lowering the panel.

Rear Access Panel

secured with 6 screws

(3 on each side)

6)Push black knob onto speed control.

7)Re-attach control panel with 3 screws, reversing step 2.

8)Mount the blower assembly in position un- der the base of the stove and secure with the 2 supplied bolts (2-1/4" #20 hex head)

Waterford TARA T25 Direct Vent Freestanding Gas Stove

7

Page 7
Image 7
Waterford Appliances T25-LP, T25-NG Optional Fan Installation, Locating Your Gas Stove, TARA Clearances, Fan Kit Contains