| on each side of the sections identifies the stacking sequence. The sequence is always deter- |
|
|
| mined by #1 being the bottom section to #7 or #8 being the highest top section. If the stamp on |
|
|
| the section is illegible, refer to the section side view illustration. The section side view illustration |
|
|
| shows the section profile of all sections, and can also be used to identify each section. |
5/16” x | Cotter pin | Cable drums RH/LH Torsion springs RH/LH | The BOTTOM SECTION can be identified by #1. |
Clevis pin (as required) | (as required) | The INTERMEDIATE I SECTION can be identified by #2. | |
|
|
|
The INTERMEDIATE II SECTION can be identified by #3, for a 4 section high door only.
|
|
|
| The INTERMEDIATE III SECTION can be identified by #4, for a 5 section high door only. | |
| Center bearing bracket | Center bearing bracket | Key shafts | The INTERMEDIATE IV SECTION can be identified by #5, for a 6 section high door only. | |
(2) Cable sheaves | The INTERMEDIATE V SECTION can be identified by #6, for a 7 section high door only. | ||||
assembly (as required) | assembly (as required) | (as required) |
|
|
|
|
|
|
| The TOP SECTION can be identified by a #, being the highest section. |
|
|
|
| ||||
|
|
|
|
|
|
| Typical design option “Outside surface of |
|
| Top rail |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| door sections shown” |
|
|
|
|
|
|
| |
Center coupler |
| Cable sheave | Oval Bearings | Counterbalance |
|
|
|
|
|
|
|
|
| ||
assembly (as required) |
| saddles (as required) | (as required) | lift cables |
|
| 4. or 3. |
| Outside |
| Inside |
| |||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| Top |
|
|
| |||
|
|
|
|
|
|
|
|
|
| surface |
| surface |
| ||
|
|
|
|
|
|
|
|
| section |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| 3. |
|
|
| Typical |
| |
|
|
|
|
|
|
|
|
| Intermediate II |
|
|
| |||
Strut clips |
|
|
|
|
|
|
|
|
|
| stamping |
| |||
|
|
| Half Center |
| Weather seals |
|
| section |
|
|
|
| |||
|
|
|
|
|
|
|
|
| location |
| |||||
(as required) |
| Hinges | hinges (as required) | & nails (If included) |
|
| 2. | # |
| # | 1 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Intermediate I | Bottom |
| Bottom |
| ||
|
|
|
|
|
|
|
|
| section |
| rail |
| rail |
|
|
|
|
|
|
|
|
|
|
| 1. |
| Side views of sections |
| |||
Bottom weather seal with |
| Lift handles | Pull down rope |
|
|
| Bottom | Top | Intermediate(s) | Bottom | |||||
3/4” nails (as required) |
| (as required) | (if included) | Track bolts (as required) |
|
| section | ||||||||
|
|
| section |
|
| section | |||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| NOTE: 3 Section high doors, does not have |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| an Intermediate II Section. |
|
|
|
|
|
|
| |
Truss head bolts | (2) 3/8”- 16 Hex nuts | Lag screws (as required) | Graduated End Hinge And |
|
|
| |||||||||
| Strut Identification |
|
|
|
| ||||||||||
(2) |
|
|
|
| 1/4” - 14 x 1” |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Graduated End Hinge Schedule |
|
|
|
|
| ||
|
|
|
|
|
|
| Door Height | Track |
| Section Type |
| Graduated End Hinge | |||
|
|
|
|
|
|
|
|
|
| Number |
| ||||
|
|
|
| 5/16” x 2” |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| Top |
|
| N/A |
|
| |||
|
|
|
|
| lag screw (as required) |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| 2” |
| Intermediate I |
| #2 |
|
| |
|
|
|
|
|
|
| 3 Section High Door |
|
| Bottom |
|
| #1 |
|
|
|
|
|
|
|
|
|
|
| Top |
|
| N/A |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
1/4”- 20 Flanged | 3/8” Washers |
|
| 3” |
| Intermediate I |
| #4 |
|
| |||||
hex nuts (as required) |
| (as required) | carriage bolts (as required) | nut (as required) |
|
|
| Bottom |
|
| #3 |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| Top |
|
| N/A |
|
|
|
|
|
|
|
|
|
| 2” |
| Intermediate II |
| 3# |
|
| |
|
|
|
|
|
|
|
|
| Intermediate I |
| 2# |
|
| ||
|
|
|
| 5/16” x 2” Hex head lag screws |
|
|
|
|
|
| |||||
|
|
|
|
|
|
| Bottom |
|
| 1# |
|
| |||
|
|
|
|
|
| (as required) | 4 Section High Door |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Top |
|
| N/A |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| 3” |
| Intermediate II |
| 5# |
|
| |
1/4” - 10 x 1” |
|
|
|
|
|
| Intermediate I |
| 4# |
|
| ||||
|
|
|
|
|
|
| |||||||||
hex head lag screw (as required) |
|
|
|
| Bottom |
|
| 3# |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| Top |
|
| N/A |
|
|
|
|
|
|
|
|
|
|
|
| Intermediate III |
| 4# |
|
| |
|
|
|
|
| 1/4” - 20 x 1 7/8” |
| 2” |
| Intermediate II |
| 3# |
|
| ||
|
|
|
| Carriage bolts (as required) |
|
|
| Intermediate I |
| 2# |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| 5 Section High Door |
|
| Bottom |
|
| 1# |
|
|
|
|
|
|
|
|
|
|
| Top |
|
| N/A |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| 5/16” x 1 5/8” Hex head lag screws |
|
|
| Intermediate III |
| 6# |
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||||||
drilling screws (as required) |
|
|
| (as required) |
| 3” |
| Intermediate II |
| 5# |
|
| |||
Door Section Identification |
|
|
| Intermediate I |
| 4# |
|
| |||||||
|
|
| Bottom |
|
| 3# |
|
|
When installing your door, you must use sections of the appropriate height in the right stacking location. Determine, what sections you need to use in what order depends on the design of your door.
Sections are stamped for identification, #1, #2, #3, #4, #5, #6, #7, and #8. The stamp, located 4
Please Do Not Return This Product To The Store. Contact your local
refer to your local yellow pages business listings or go to the Find a Dealer section online at