Power supply cord

NOTE: Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers.

1

Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.

Power supply cord

Wiring requirements

plug outlet

 

 

115 volt (103.5 min. -

 

126.5 max.)

 

0-12 amperes

 

15-amp time-delay fuse or

 

circuit breaker

 

Use on single outlet circuit

 

only.

1. Cabinet louvers

Window installation

Window opening measurements:

27 in. (68.6 cm) minimum to 40 in. (101.6 cm) maximum opening width.

19 in. (48.3 cm) minimum opening height.

1/4"

(0.6 cm)

230 volt (207 min. -

253 max.)

0-12 amperes

15-amp time-delay fuse or circuit breaker

Use on single outlet circuit only.

A

B

A. 27 in. (68.6 cm) minimum

B. 19 in. (48.3 cm) minimum

Electrical Requirements

Wiring requirementsWARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located on the right-hand side of the cabinet.

Recommended ground method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer's responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical installer.

It is the customer's responsibility:

To contact a qualified electrical installer.

To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances.

Copies of the standards listed may be obtained from:

National Fire Protection Association

One Batterymarch Park

Quincy, Massachusetts 02269

4

Page 4
Image 4
Whirlpool 1187361 Electrical Requirements, Window installation, Electrical Shock Hazard, Do not use an extension cord