DIRECT SPARK IGNITION CONTROL

DIRECT SPARK IGNITION CONTROL

The Direct Spark Ignition (DSI) Control inter- faces with the Electronic Oven Control for the Bake, Broil, and Self-Clean functions. The DSI also interfaces with the four cooktop burner ig- nition switches, to provide ignition for the cooktop.

DIRECT SPARK

J1

IGNITION CONTROL

10 9 7 6 4 3 2 1

10-PIN CONNECTOR

The DSI control uses a self-diagnostic test to verify that the oven ignition system is working properly. It will also continually monitor the flame presence within the oven. The DSI con- trol operates on 102 to 132 VAC. All input and output testing is performed at the J1 connec- tor (see below).

TOP BURNERS

GND BAKE BROIL

J1

DIRECT SPARK IGNITION ELECTRONIC CONTROL

Bake Valve Output DIRECT SPARK IGNITION ELECTRONIC CONTROLManual background 1

Valve Common Manual backgroundManual backgroundManual background 2

Broil Valve Output Manual backgroundManual background 3

Neutral Manual backgroundManual backgroundManual background 4

Bake Input Manual backgroundManual background 6

Broil Input Manual backgroundManual backgroundManual background 7

Top Burner Input Manual backgroundManual background 9

L1 Manual backgroundManual backgroundManual background 10

 

T4

 

 

J7

 

 

 

Right Front Spark Output

J8

T3

J1

 

 

 

J5

 

Left Front Spark Output

 

 

 

 

 

Right Rear Spark Output

 

J6

 

Left Rear Spark Output

 

T2

 

 

 

 

 

 

J2

 

Chassis Ground

J4

 

 

 

T1

Bake Burner Spark Output

J3

Broil Burner Spark Output