![OVEN BURNER OPERATION](/images/new-backgrounds/72673/7267325x1.webp)
OVEN BURNER OPERATION
The spark ignition for the oven burners is started at the Electronic Oven Control (ERC). As the ERC is programmed for Bake or Broil, the appropriate relay is closed on the ERC. 120 VAC is provided from L1, through the ERC relay(s) to the direct spark ignition control at input pin
This 120 VAC is used to generate two sparks-
L1 | OVEN CONTROL (ERC) |
|
|
|
| N | |
|
|
|
|
|
| ||
|
| BROIL |
|
|
|
|
|
BK | RELAY |
|
|
|
|
| |
|
|
|
|
|
| ||
V |
|
|
|
|
| BAKE VALVE | |
|
|
|
|
|
|
| |
OVEN |
|
|
|
|
|
|
|
TEMP |
| R |
|
|
| R | |
SENSOR |
|
|
|
| |||
V |
|
|
|
|
| OR W | |
| RELAY |
|
|
|
| ||
BK |
|
|
|
|
|
|
|
|
|
| J1 | 10 9 | 7 6 | 4 3 | 2 1 |
|
|
|
| ||||
|
| DIRECT SPARK |
| GND BAKE BROIL | |||
|
| IGNITION CONTROL | |||||
|
|
|
|
| |||
|
| Bake Operation |
|
|
|
|
|
|
|
|
|
|
|
| BROIL VALVE |
L1 | OVEN CONTROL (ERC) |
|
|
|
| N |
| BROIL | |
BK | RELAY |
|
| ||
| V |
|
|
|
BU
OR W
OVEN |
|
| J1 | 10 9 | 7 6 | 4 3 | 2 1 |
TEMP |
|
|
| ||||
SENSOR |
|
|
| ||||
BAKE | DIRECT SPARK |
|
|
| |||
V |
|
|
| ||||
| RELAY | IGNITION CONTROL | GND BAKE BROIL | ||||
|
|
BK
Broil Operation
Monitoring System
When power is applied to the range, a safety delay of 40 seconds takes place before the direct spark ignition control becomes opera- tional. The 40 second delay allows any unused gas inside the oven cavity to dissipate before a spark is activated. When the Bake or Broil operation is activated, the direct spark ignition control initiates an “internal
The
- 9 -