4.Touch the test leads to the J1 connector at terminals 4 (white) and 7 (blue/white). The AC voltmeter should indicate 120 VAC. If not, check the electronic oven control for proper operation.
4 (white) | 7 (blue/white) |
J1 Connector
5.Set the voltmeter to read between 8 and 18 volts DC.
6.Touch the test leads to the J1 connector at terminals 2 (orange) and 3 (blue). The DC voltmeter should indicate between 8 and 18 volts DC*. If not, replace the DSI con- trol.
2 (orange) 3 (blue)
J1 Connector
*When power is applied to the range, a safety delay of 40 seconds takes place before the direct spark ignition control becomes operational. The opera- tion will last for a period of 4 seconds, and the direct spark ignition will again turn off (see the “Timing Chart” for the oven burners on page 10).
Broil Strip Circuit
BROIL VALVE
L1 | OVEN CONTROL (ERC) | N |
| BROIL | |
BK | RELAY |
|
| ||
| V |
|
|
|
BU
OR W
OVEN |
|
| J1 | 10 9 | 7 6 | 4 3 | 2 1 | |
TEMP |
|
|
| |||||
SENSOR |
|
|
| |||||
BAKE |
|
|
|
|
| |||
V | DIRECT SPARK | GND BAKE BROIL | ||||||
| RELAY | |||||||
|
| IGNITION CONTROL | ||||||
|
|
|
|
|
|
BK
- 15 -