REMOVING THE GAS DISTRIBUTION VALVE
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range.
Replace all panels before operating range.
Failure to do so can result in death or electri- cal shock.
FIRE HAZARD
Shut off gas supply line valve before servic- ing the range.
Check all gas line connections and replace all panels before operating the range.
Failure to do so could result in explosion, fire, or other injury.
3.Remove the gas outlet lines from the gas distribution valve with a 9/16˝
4.Remove the four mounting screws from the gas distribution valve.
Gas Outlet | Screws |
|
Gas
Distribution
Valve
CAUTION: When you work on the gas range, be careful when handling the sheet metal parts. Sharp edges may be present, and you can cut yourself if you are not careful.
1.Turn off the gas to the range and discon- nect the power cord from the wall outlet.
2.Pull the range away from the wall so you can access the back of the unit.
Gas Outlet | Screws |
|
5.Lower the gas distribution valve so that it is free of the bake burner, and lay it down, as shown below.
Gas Distribution Valve
(Back of Range)
6.Remove the electrical connections. NOTE: The terminals are different sizes to pre- vent miswiring (see page 4).
- 12 -