Whirlpool KR-28 manual Bake & Broil Solenoid- Activated Ports, neither one will operate

Models: KR-28

1 29
Download 29 pages 14.12 Kb
Page 8
Image 8
BAKE & BROIL SOLENOID- ACTIVATED PORTS

BAKE & BROIL SOLENOID- ACTIVATED PORTS

The bake and broil gas supply ports are opened and closed by electrically-operated solenoids. When voltage is received from the spark ignition control for the bake or broil function, (8-18 VDC), the solenoid for that function is activated, and the valve opens to allow gas

flow to the burner. The electrical connections at the valve consist of three terminals, each one sized differently to prevent incorrect wir- ing (see below).

The solenoids require special voltage/current (8 - 18 VDC) from the direct spark ignition con- trol to operate properly. IMPORTANT: Do not attempt to operate the solenoids with any other voltage supply.

Manual Oven

Shutoff Valve

Electrical Terminals:

Broil = 1/8˝ wide Manual Oven

Common = 1/4˝ wide Common = 1/4˝ wide

Bake = 3/16˝ wide Each Solenoid Terminal

216 Resistance Across

Each Solenoid Terminal

8 to 18 VDC

NOTE: Always check

both solenoids. If either

solenoid is defective,

neither one will operate.

- 4 -

Page 8
Image 8
Whirlpool KR-28 Bake & Broil Solenoid- Activated Ports, Manual Oven Shutoff Valve Electrical Terminals Broil = 1/8˝ wide