Whirlpool W4GH6 Normal Operating Pressures, Temperature of the Air, Entering the Outdoor Coil

Models: W4GH6

1 20
Download 20 pages 46.03 Kb
Page 8
Image 8
Normal Operating Pressures

Normal Operating Pressures

NOTE: Values provided in chart are typical pressures. Indoor unit matchup, indoor air quality and indoor load will cause pressures to vary.

 

Model

 

 

 

 

 

 

 

Temperature of the Air

 

 

 

 

 

 

 

 

-24

 

-36

 

-48

 

-60

 

Entering the Outdoor Coil

 

 

 

 

 

 

 

 

Liquid

Suction

Liquid

Suction

Liquid

Suction

Liquid

Suction

 

 

 

 

 

 

 

 

 

Cooling—1st Stage (Low Capacity)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65ºF

232

146

225

144

235

144

225

138

 

 

 

 

 

 

 

 

 

75ºF

264

148

261

147

268

145

264

141

 

 

 

 

 

 

 

 

 

85ºF

307

149

302

149

310

147

305

142

 

 

 

 

 

 

 

 

 

95ºF

353

151

349

151

356

148

352

146

 

 

 

 

 

 

 

 

 

105ºF

403

153

397

153

407

150

405

148

 

 

 

 

 

 

 

 

 

115ºF

460

155

461

157

466

152

459

150

 

 

 

 

 

 

 

 

Cooling—2nd Stage (High Capacity)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65ºF

240

143

239

139

244

140

241

134

 

 

 

 

 

 

 

 

 

75ºF

279

145

278

141

283

141

280

136

 

 

 

 

 

 

 

 

 

85ºF

322

147

322

143

326

144

324

137

 

 

 

 

 

 

 

 

 

95ºF

371

149

367

146

374

147

373

138

 

 

 

 

 

 

 

 

 

105ºF

423

151

426

148

427

148

425

142

 

 

 

 

 

 

 

 

 

115ºF

485

154

489

151

491

151

486

146

 

 

 

 

 

 

 

 

Heating—1st Stage (Low Capacity)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40ºF

337

93

328

98

369

75

351

63

 

 

 

 

 

 

 

 

 

50ºF

322

117

333

118

366

114

335

92

 

 

 

 

 

 

 

 

Heating—2nd Stage (High Capacity)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20º

279

62

296

62

311

58

308

59

 

 

 

 

 

 

 

 

 

30ºF

288

76

309

75

334

72

323

70

 

 

 

 

 

 

 

 

 

40ºF

302

93

322

92

354

89

318

69

 

 

 

 

 

 

 

 

 

50ºF

306

112

336

113

381

108

329

82

 

 

 

 

 

 

 

 

 

8

Page 8
Image 8
Whirlpool W4GH6 Normal Operating Pressures, Temperature of the Air, Entering the Outdoor Coil, Liquid, Suction, Model