Whirlpool W4GH6 Minimum Clearances, Line Set Isolation, Installing Horizontal Runs, C To

Models: W4GH6

1 20
Download 20 pages 46.03 Kb
Page 3
Image 3
Minimum Clearances

Minimum Clearances

A B

C To

D

 

Power

 

48" Overhead

Supply

To

 

Clearance

 

Indoor

(Discharge

 

Unit

Air)

 

12" Clearance

 

To

 

Indoor

(Inlet Air)

 

 

Coil

E

36" Clearance

 

30" Service

12" Clearance Between

(Inlet Air)

Access Clearance

Unit and Building

 

 

 

A. Weatherproof disconnect switch

D. House thermostat

B. NEC class 1 wiring

 

E. Seal openings

C. NEC class 2 wiring

 

 

Line Set Isolation

The following illustrations demonstrate procedures which ensure proper refrigerant line set isolation.

Installing Horizontal Runs

This shows how to install line sets on horizontal runs.

NOTE: To hang line set from joist or rafter, use either metal strapping material or anchored heavy nylon wire ties.

 

C

8'

 

B

D

 

 

8'

E

G

 

A

 

F

 

A. Metal strapping material

E. Metal sleeve

(around vapor line only)

F. Tape or anchored heavy nylon

B. Floor joist or roof rafter

wire tie

C. Anchored heavy nylon wire tie

G. Strap the vapor line to the floor

(around vapor line only)

joist or roof rafter at 8" intervals,

D. Tape or wire tie

then strap the liquid line to the

 

vapor line.

Transition from Horizontal to Vertical

This shows how to make a transition from horizontal to vertical.

Style 1

 

Style 2

 

A

 

G

 

 

B

 

B

 

 

 

 

C

 

C

 

 

 

F

 

F

 

 

D

D

E

E

A. Style 1—anchored

C. Liquid line

E. Metal sleeve

heavy nylon wire tie

D. Vapor line—

F. Wall stud

 

B. Strap liquid line to

wrapped in

G. Style 2—automotive

vapor line.

armaflex

muffler-type hanger

Installing Vertical Runs (new construction shown)

This shows how to install line sets on vertical runs.

NOTE: Similar installation practices should be used if line set is to be installed on exterior of outside wall.

IMPORTANT: Refrigerant lines must not contact structure.

 

 

B

 

 

C

A

C

 

H

D

 

 

 

 

D

E

 

 

F

 

G

 

 

 

G

 

 

 

 

 

 

H

 

C

 

E

A

 

 

I

 

 

 

 

 

 

E

 

 

J D

G

 

 

 

L

K

 

H

 

 

 

A. Outside wall

 

D. Liquid line

I. Wood block

B. Refrigerant lines

E. Anchored heavy nylon

between studs

must not contact

wire tie

J. Caulk

wall.

 

F. Inside wall

K. Fiberglass

C. Vapor line wrapped

G. Metal strapping material

insulation

in armaflex

 

H. Metal sleeve

L. PVC pipe

3

Page 3
Image 3
Whirlpool W4GH6 Minimum Clearances, Line Set Isolation, Installing Horizontal Runs, Transition from Horizontal to Vertical