Whirlpool W4GH6 installation instructions Heat Pump Safety, Installation Requirements, 48488A006

Models: W4GH6

1 20
Download 20 pages 46.03 Kb
Page 1
Image 1
HEAT PUMP INSTALLATION INSTRUCTIONS

HEAT PUMP INSTALLATION INSTRUCTIONS

Table of Contents

HEAT PUMP SAFETY

1

INSTALLATION REQUIREMENTS

1

Tools and Parts

2

System Requirements

2

Location Requirements

2

Electrical Requirements

4

Inspect Shipment

4

Flush Refrigerant Lines

4

Connect Refrigerant Lines

6

Make Electrical Connections

9

Complete Installation

11

SEQUENCE OF OPERATION

12

Cooling Cycle

12

Heating Cycle

12

Defrost Cycle

12

Adjust Defrost System

13

Troubleshoot the Defrost System

14

TROUBLESHOOTING

15

System Diagnostic Module

15

SYSTEM MAINTENANCE

17

ASSISTANCE OR SERVICE

17

Accessories

17

WARRANTY

18

HEAT PUMP SAFETY

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:

Table of ContentsDANGER

HEAT PUMP SAFETYWARNING

You can be killed or seriously injured if you don't immediately follow instructions.

You can be killed or seriously injured if you don't follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

INSTALLATION REQUIREMENTS

These instructions are intended as a general guide only for use by qualified persons and do not supersede any national or local codes in any way. The installation must comply with all state and local codes as well as the National Electrical Code

The heat pump is designed and approved for outdoor use only.

The heat pump must be installed with no ductwork in the airstream. The outdoor fan is not designed to operate against any additional static pressure.

Whirlpool GoldModel W4GH6