!CAUTION

If the outside temperature is below 50°F,

DO NOT use the button to move the temperature below the setpoint tempera- ture. Property damage may result due to compressor slugging.

11.Why doesn’t the temperature change at the time I programmed?

There are a number of causes for this situ- ation. The following are primary reasons.

The EMR function is operating. The EMR function will automatically turn on the system early enough to bring the temperature to the selected level by the beginning of the next program pe- riod. See OPERATING YOUR THERMOSTAT.

You have programmed the incorrect day or time. Check your programming (be sure that the times you programmed are correct AM or PM times). See PRO-

GRAMMING YOUR THERMOSTAT.

The thermostat is in the HOLD mode.

RUN

Press PRGM to start program operation.

See OPERATING YOUR THERMO- STAT.

The compressor lockout feature is oper- ating; wait about 5 minutes for system to begin running. See OPERATING YOUR THERMOSTAT.

37

Page 37
Image 37