MACHINE TROUBLESHOOTING
PROBLEM | CAUSE |
| SOLUTION | ||
|
|
|
|
|
|
Vacuum motor does not run, | Recovery tank full |
| Drain recovery tank |
| |
or runs slowly |
|
|
|
|
|
| Recovery tank float |
| Clean float switch | ||
| switch dirty |
|
|
|
|
| Loose motor connection |
| Check motor wires and | ||
|
|
| connections | ||
| Worn vacuum motor |
| Replace brushes, check | ||
| brushes |
| commutator | ||
Poor scrubbing performance | Debris caught in scrub |
| Remove debris |
|
|
| brushes |
|
|
|
|
| Worn brushes or pads |
| Replace brushes or pads | ||
|
|
|
|
|
|
| Improper detergent, |
| Contact equipment or | ||
| brush or pad used |
| application specialists | ||
| Low scrub brush down |
| Increase brush pressure | ||
| pressure |
|
|
|
|
| Low battery charge |
| Charge batteries | ||
|
|
|
|
|
|
Little or no solution flow to the | Solution tank empty |
| Fill solution tank | ||
floor |
|
|
|
|
|
| Solution flow turned off |
| Turn on or increase flow | ||
| or set too low |
| setting | ||
| Solution strainer plugged |
| Clean solution strainer | ||
|
|
|
|
|
|
| Solution system |
| Clear obstruction from | ||
| plumbing obstructed |
| plumbing | ||
| Solution solenoid valve |
| Clean or replace valve | ||
| obstructed or stuck |
|
|
|
|
| Vent hole in solution |
| Clear obstruction from vent | ||
| tank lid obstructed |
| hole | ||
| Faulty solenoid valve |
| Check wiring to solution valve | ||
| connection |
|
|
|
|
Brush motors do not run, or | Circuit breaker(s) tripped |
| Reset circuit breaker(s) | ||
run slowly |
|
|
|
|
|
| Low battery charge |
| Charge battery | ||
|
|
|
|
|
|
| Loose connection |
| Check motor wires and | ||
|
|
| connection | ||
| Worn brush motor |
| Replace brushes, check | ||
| brushes |
| commutator | ||
Scrub deck will not go | Faulty actuator |
| Repair/replace actuator |
| |
down/up |
|
|
|
|
|
| Loose connection |
| Check motor wires and | ||
|
|
| connections | ||
Scrub deck goes down, then | No brushes or pad |
| Install brushes or pad drivers |
| |
raises | drivers on machine |
|
|
|
|
Error code not listed is | Controller detects |
| Contact service technician | ||
displayed | electrical problem |
|
|
|
|
| SGJ32 86037680 01/03/07 |