Wolf Cinema Owner's Manual B-26
3.65 HDl
DHDM look Thru setting HDl DHDM loop Thru setting
When the Dual SD/HD-SDi module is present, a serial input may be routed to a serial output to
allow chaining of signal sources using the HDl command. you can specify which input is routed
to which output. Primary and Secondary sources may also be used as designated inputs to loop
tooutputs.P1denestheoptioncardslotyouwishtocongureandP2referstowhatloopthru
inputs and outputs are desired. The table below lists the value options.
Value Input Output
0a C
B D
1a D
B C
2 Primary C
Secondary D
3 Primary D
Secondary C
examples:
(HDl 2 3) Set loop thru on option slot 2 to be: Primary thru to D and
Secondary thru to C
(HDL?2) Requestloopthruforslot2only;returns(HDL!002003)forabove
setting.
(HDL?) Requestloopthruforeitherslot;returns(HDL!001001)
(HDl! 002 003) if cards exist in both slots.
HIs lamp History
Use the read-only HiS request to obtain the projector’s lamp history. note for dual-lamp, this
information is stored separately for each lamp (P1 identies Lamp 1 or 2)—see examples
below.
examples:
(HiS? 1) What is the lamp 1 history?
(HIS!00100100555“000000014”) //Lamp1,sn.=”000000014”,rstlamp
used, on for 555 hours
(HiS! 001 002 00095 “000000018”) // lamp 1, sn.=”000000018”, second
lamp used, on for 95 hours
(HiS?) What is the complete lamp history for lamp 1 and lamp 2?
(HIS!00100100555“000000014”) //Lamp1,sn.=”000000014”,rstlamp
used, on for 555 hours
(HiS! 001 002 00095 “000000018”) // lamp 1, sn.=”000000018”, second
lamp used, on for 95 hours
(HIS!00200100666“000000022”) //Lamp2,sn.=”000000022”,rstlamp
used, on for 666 hours
3.66 HIss
lamp History
AppendixB►SerialCommunications