Woods Equipment 8100, 8000 manual Connect the Hydrostatic Control Cable, Connect PTO Shaft

Models: 8100 8000

1 40
Download 40 pages 29.25 Kb
Page 11
Image 11
Connect the Hydrostatic Control Cable

A S S E M B L Y

Connect the Hydrostatic Control Cable

(For models with factory installed hydraulic feed.)

1.Remove the clevis assembly from the hydrostatic control cable end (see figure 4). Remove one nut on the cable end. Insert the cable end into the hole in the cable anchor weldment. Replace the nut and the clevis assembly.

2.Attach the clevis assembly to the center hole on the feed control lever.

3.Adjust the cable detent ball to contact the detents in the cable anchor weldment when the control arm is in the forward position or reverse position.

Important! See hydrostatic pump start-up procedure.

Connect PTO Shaft

1.Connect the PTO shaft female end to the rotor shaft using key stock and two set screws contained in the owner's kit.

2.Connect the opposite end of the PTO shaft to the tractor.

3.Check all screws, bolts, and nuts for tightness. See torque chart, page 5 for minimum tightening torque.

Insertcable

 

Clevis

Detent

Nut

Assembly

Ball

throughhole

 

 

 

FeedControl

Lever

CableAnchor

Weldment

Hydrostat

ControlCable

Figure4

PN-51210 (Rev. 7/98)

9

Page 11
Image 11
Woods Equipment 8100, 8000 manual Connect the Hydrostatic Control Cable, Connect PTO Shaft