H Y D R A U L I C F E E D M A I N T E N A N C E

HydraulicFeedMaintenance

Contactyourdealeror

factoryservice

departmentBefore

servicingorrepairing anyofthehydrostatic feedcomponents(pump, motor,and/orrelief valve).Warrantyon theseitemsmaybevoid withoutprior authorization.

NOTE: Check the reservoir daily for proper fluid level, the presence of water (noted by a cloudy to milky appearance or free water in bottom of reservoir), and rancid fluid odor (excessive heat).

The hydrostatic pump normally does not require regular fluid changes. Change the system filter at 250 hour or annual intervals. Change the fluid and filter and clean the system if the fluid becomes contaminated with foreign matter (water, dirt, grease, etc.) or if the fluid has been subjected to temperature levels greater than the recommended maximum.

There is a greaseable bearing on each side of the main jack shaft on the main hydraulic feed housing. Grease periodically.

HydrostaticPumpTroubleshooting

Symptom

Probable Cause

SuggestedRemedy

 

 

 

Willnotattainnormalfeedrate.

Engine not operating at

Repair engine governor.

 

correct speed.

 

 

Control linkage damaged or

Repair control linkage.

 

binding.

 

 

Bypass valve stuck partially

Repair bypass valve.

 

 

 

open. (Problem in one

Removeforeignmaterialfrom

 

direction only.)

 

valve.

 

 

 

 

 

Willnotfeedwhencontrolarm

Control linkage damaged or

Repair or reconnect control

ismoved.

notconnected.

linkage.

 

Drive between engine and

Repair drive (replace broken

 

pumpdamaged.

belt, repair sheared key, re-

 

 

pair splined coupling, etc.).

 

Pump low on fluid.

Refill reservoir. Purge air from

 

 

transmission.

 

 

 

Feed rate is sluggish under

Loose drive belt between

Tension drive belt (replace if

load.

engineandpump.

necessary).

 

Pump low on fluid.

Refill reservoir. Purge air from

 

 

transmission if necessary.

 

Large amount of water in hy-

Drain fluid from reservoir and

 

draulicfluid(evaporateswhen

unit, replace filter element,

 

hot, resulting in low fluid level).

and refill with new fluid.

 

 

 

Hydraulic Feed will not pull in

Hydraulicsystemoverloading

Check relief pressure in sys-

logs over 4" in diameter, or

and causing system to go

tem with a pressure gauge

continuously stalls or stops.

over relief

ratedto2500psi.(Systemset

 

 

by factory at 1750 psi.)

 

 

 

PN-51210 (Rev. 7/98)

24

Page 26
Image 26
Woods Equipment 8000, 8100 manual HydraulicFeedMaintenance, HydrostaticPumpTroubleshooting