Operation

Battery Charging

Completely recharging wet cell deep-cycle batteries requires that the battery voltage be raised beyond what is known as the gassing point. This is the voltage at which the battery begins to bubble and gas is given off. If charging stops short of this point, sulfate is left on the plates and deterioration of the battery begins. The gassing point will vary with battery temperature. At 25 degrees C, the gassing point of a 12-volt battery is about 14.0 volts. Battery charging without excessive gassing of the batteries is accomplished with three-stage chargers. This technique is used in the Freedom 10.

Gel cell batteries must not be charged to their gassing point. In fact high voltage charging that gasses these batteries is harmful to them. These batteries do not give off water vapor. The float voltage can be higher than that of wet cell batteries.

Conventional Battery Chargers

Most conventional battery chargers are single stage constant voltage chargers. As such they must stop short of the gassing point or they will overcharge the battery bank. Therefore, most 12-volt battery chargers bring the battery voltage up to about 13.8 volts.

There are two problems with this. First, since the battery voltage does not reach the gassing point, sulfate is left on the plates. Second, 13.8 volts is close enough to the gassing point that some gas will escape, and the battery will need to be frequently topped up with distilled water.

Conventional battery chargers also suffer from another inherent characteristic of their design, which is a tapering output. While they will deliver their rated current into a deeply discharged battery, as the battery becomes charged and the voltage rises, the output current of the charger tapers down. This taper continues as the battery is charged, taking a very long time to reach an acceptable recharge.

The Freedom Battery Charger

The Freedom battery chargers are designed to overcome the limitations of conventional chargers by utilizing three distinct stages, each designed for optimal recharging of both wet cell and gel cell deep-cycle batteries.

Important: The Freedom 10 Battery Charger is on whenever there is AC power connected to the charger input, regardless of the condition of the ON/OFF switch.

Each time the battery charger is engaged, the three stages proceed automatically, resulting in an efficient, complete recharge and safe battery maintenance. In addition, use of the remote control provides the ability to periodically apply an 8-hour timed equalizing charge.

3–12

975-0251-01-01

Page 50
Image 50
Xantrex Technology 10 owner manual Battery Charging, Conventional Battery Chargers, Freedom Battery Charger