Installing the Inverter/Charger

Mounting to the Negative Battery Terminal

To mount the sensor on the negative battery terminal:

Negative (–)

battery terminal

Figure 7 BTS Mounted on the Negative Battery Terminal

1.Select the battery to be monitored. The BTS should be connected to the battery bank that is directly connected to the inverter/charger.

2.Switch off all devices operating from the battery, or open the battery switch (if present) to disconnect the battery.

3.Wait 10 minutes for any explosive battery gases to dissipate.

4.Remove the nut that connects existing wiring ring terminals to the battery negative terminal stud.

5.Move or reorient the existing wiring ring terminals on the battery negative terminal stud, so there is a flat surface on which to seat the BTS mounting plate.

You may need to bend the ring terminal crimp and/or wires slightly downward to allow the sensor to seat flush to the top surface of the upper ring terminal.

6.Mount the sensor directly on top of the ring terminal, as shown in Figure 7, and firmly tighten the terminal nut.

FIRE HAZARD

In this procedure, you must install the DC wire on the battery terminal, then install the sensor on top of the DC wire. This sequence is required to provide the best connection to the battery and to ensure correct performance of the sensor.

Failure to follow these instructions will result in death or serious injury.

7.Check to ensure that the sensor and all wires are held firmly and cannot be moved.

8.Turn the battery switch on again (if you opened it in Step 2.)

9.Route the sensor cable to the inverter/charger and plug it into the BTS jack, as shown in Figure 8. Secure the cable along its length.