SECTION 5

TROUBLESHOOTING

FAULT DESCRIPTIONS AND TROUBLESHOOTING

FAULT DESCRIPTIONS

Fault Description

Fault Code (LCD)

 

 

IPM Device Fault A+

0x0001

 

 

IPM Device Fault A-

0x0002

 

 

IPM Device Fault B+

0x0004

 

 

IPM Device Fault B-

0x0008

 

 

IPM Device Fault C+

0x0010

 

 

IPM Device Fault C-

0x0020

 

 

AC Line Under Voltage

0x0100

 

 

AC Line Over Voltage

0x0200

 

 

AC Line Under Frequency

0x0400

 

 

AC Line Over Frequency

0x0800

 

 

Ground Current Fault

0x8000

 

 

DC Bus Over Voltage

0x4000

 

 

CT Offset Fault

80000

 

 

Current Imbalance

100000

 

 

(1) IPM Device Fault (0x0001 Through 0x0020)

Both over current and over temperature condition can cause IPM device faults. The fault code for both conditions is the same for each device, while there is a unique fault code for each device.

Possible causes for over current condition:

Short circuit in output AC line.

Low supply voltage to IPM control circuit.

Shorted isolation transformer.

Possible causes for over temperature condition:

External cooling fan inoperable.

Airflow on heatsink impeded due to accumulation of debris.

Operation above rated ambient temperature for an extended period of time.

Auxiliary contact block on contactor K1 inoperable. This is only possible if the fan does not operate

DOCUMENT: 151315PV-30208 Photovoltaic Inverter5-2

Operation and Maintenance Manual

Copyright 2003, Xantrex Technology Inc.

Page 26
Image 26
Xantrex Technology PV-30208 important safety instructions Fault Descriptions, IPM Device Fault 0x0001 Through