SCPI Command Summary
TM-XDOP-01XN C–15
Set High Current
Limit [[:]SOURce][<channel>]:CURRent:LIMit:HIGH
{<current>|MAXimum|MINimum} Set upper limit of current setpoint
range (soft limits) Yes
Set Low Current
Limit [[:]SOURce][<channel>]:CURRent:LIMit:LOW
{<current>|MAXimum|MINimum} Set lower limit of current setpoint
range (soft limits) Yes
Set High Power
Limit [[:]SOURce][<channel>]:POWer:LIMit:HIGH
{<power>|MAXimum|MINimum} Set upper limit of power setpoint
range (soft limits) Yes
Set Low Power
Limit [[:]SOURce][<channel>]:POWer:LIMit:LOW
{<power>|MAXimum|MINimum} Set lower limit of power setpoint
range (soft limits) Yes
Set High Voltage
Limit [[:]SOURce][<channel>]:VOLTage:LIMit:HIGH
{<voltage>|MAXimum|MINimum} Set upper limit of voltage setpoint
range (soft limits) Yes
Set Low Voltage
Limit [[:]SOURce][<channel>]:VOLTage:LIMit:LOW
{<voltage>|MAXimum|MINimum} Set lower limit of voltage setpoint
range (soft limits) Yes
Table C-4Commands for Current Share
Function SCPI Command Description Query
Set Current Sharing
Mode [[:]SOURce][<channel>]:COMBine:CSHare:MODE
{NONE|MASTer|SLAVe} Select current share mode Yes
Read Summed
Current [:]MEASure[:SCALar]:CURRent[:DC]? SUM Read total current output of all
current sharing supplies N/A
Table C-3
Commands for Output Control
Function SCPI Command Description Query
TM-XDOP-01XN.book Page 15 Monday, July 17, 2006 11:19 AM