Specifications and Characteristics
A–4 TM-XDOP-01XN
Table A-3Specifications for 12000 Watt units (10V to 60V Models)
Models 10-1200 20-600 30-400 40-300 60-200
Output Ratings:
Output Voltage a
Output Current b
Output Power
a. Minimum output voltage is <0.3% of rated voltage at zero output setting.
b. Minimum output current is <0.2% of rated current at zero output setting when measured with rated load resistance.
0–10 V
0–1200 A
12000 W
0–20 V
0–600 A
12000 W
0–30 V
0–400 A
12000 W
0–40 V
0–300 A
12000 W
0–60 V
0–200 A
12000 W
Line Regulation: c
Voltage (0.01% of Vmax)
Current (0.1% of Imax)
c. For input voltage variation over the AC input voltage range, with constant rated load.
1mV
1200 mA 2mV
600mA 3mV
400mA 4mV
300mA 6mV
200mA
Load Regulation: d
Voltage (0.05% of Vmax + 5mV)
Current (0.2% of Imax + 40 mA)
d. For 0–100% load variation, with constant nominal line voltage.
10mV
2440 mA 15mV
1240 mA 20mV
840mA 25mV
640mA 35mV
440mA
Meter Accuracy:
Voltage (0.15% of Vmax)
Current (0.5% of Imax) 15mV
6A 30mV
3A 45mV
2.0A 60mV
1.5A 90mV
1A
Output Noise (0–20 MHz):
Voltage (p–p) 75mV 75mV 75mV 75mV 100mV
Output Ripple (rms):
Voltage
Current e
e. Current mode noise is measured from 10% to 100% of rated output voltage, full current, unit in CC mode.
10mV
6200 mA 10mV
3200 mA 12mV
2000 mA 15mV
1500 mA 15mV
900mA
OVP Adjustment Range:
(0% to 103% of Vmax) 0–10.3 V 0–20.6 V 0–30.9 V 0–41.2 V 0–61.8 V
Efficiency: f
f. Typical efficiency at nominal input voltage and full output power.
0.85 0.87 0.87 0.87 0.89
Drift (30 minutes): g
Voltage (0.04% of Vmax)
Current (0.6% of Imax)
g. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
4mV
7200 mA 8mV
3600 mA 12mV
2400 mA 16mV
1800 mA 24mV
1200 mA
Drift (8 hours): h
Voltage (0.02% of Vmax)
Current (0.05% of Imax)
h. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.
2mV
600mA 4mV
300mA 6mV
200mA 8mV
150mA 12mV
100mA
Temperature Coefficient: i
Voltage (0.04% of Vmax/°C)
Current (0.06% of Imax/°C)
i. Change in output per °C change in ambient temperature, with constant line and load.
4mV
720mA 8mV
360mA 12mV
240mA 16mV
180mA 24mV
120mA
TM-XDOP-01XN.book Page 4 Monday, July 17, 2006 11:19 AM