Electrical Specifications—Summary
TM-XDOP-01XN A–5
Table A-4Specifications for 12000 Watt units (80V to 600V Models)
Models 80–150 100–120 150–80 300–40 600–20
Output Ratings:
Output Voltage a
Output Current b
Output Power
a. Minimum output voltage is <0.3% of rated voltage at zero output setting.
b. Minimum output current is <0.2% of rated current at zero output setting when measured with rated load resistance.
0–80 V
0–150 A
12000 W
0–100 V
0–120 A
12000 W
0–150 V
0–80 A
12000 W
0–300 V
0–40 A
12000 W
0–600 V
0–20 A
12000 W
Line Regulation: c
Voltage (0.01% of Vmax)
Current (0.1% of Imax)
c. For input voltage variation over the AC input voltage range, with constant rated load.
8mV
150 mA 10 mV
120 mA 15 mV
80mA 30mV
40mA 60mV
20mA
Load Regulation: d
Voltage (0.05% of Vmax + 5mV)
Current (0.2% of Imax + 40 mA)
d. For 0–100% load variation, with constant nominal line voltage.
45 mV
340 mA 55 mV
280 mA 80mV
200mA 155 mV
120mA 305 mV
80mA
Meter Accuracy:
Voltage (0.15% of Vmax)
Current (0.5% of Imax) 120 mV
750 mA 150 mV
600 mA 225mV
400mA 450 mV
200mA 900 mV
100mA
Output Noise (0–20 MHz):
Voltage (p–p) 100 mV 100mV 150 mV 250 mV 350 mV
Output Ripple (rms):
Voltage
Current e
e. Current mode noise is measured from 10% to 100% of rated output voltage, full current, unit in CC mode.
15 mV
640 mA 20 mV
460 mA 20mV
240mA 30 mV
100mA 80 mV
50mA
OVP Adjustment Range:
(0% to 103% of Vmax) 0–82.4 V 0–103V 0–154.5V 0–309 V 0–618V
Efficiency: f
f. Typical efficiency at nominal input voltage and full output power.
0.89 0.90 0.90 0.91 0.91
Drift (30 minutes): g
Voltage (0.04% of Vmax)
Current (0.6% of Imax)
g. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
32 mV
900 mA 40 mV
720 mA 60mV
480mA 120 mV
240mA 240 mV
120mA
Drift (8 hours): h
Voltage (0.02% of Vmax)
Current (0.05% of Imax)i
h. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.
i. Current drift for 600V-20A unit is 0.08% of Imax.
16 mV
75 mA 20mV
60 mA 30mV
40mA 60mV
20mA 120mV
16mA
Temperature Coefficient: j
Voltage (0.04% of Vmax/°C)
Current (0.06% of Imax/°C)
j. Change in output per °C change in ambient temperature, with constant line and load.
32 mV
90 mA 40mV
72 mA 60mV
48mA 120mV
24mA 240mV
12mA