SCPI Command Summary
TM-XDOP-01XN C–27
Table C-11Protection Commands
Function SCPI Command Description Query
Set Over
Temperature
Response
[:]SENSe[<channel>]:TEMPerature:PROTection:LAT
Ch <on-off-state> Select if output is latched off or
auto recovers in the case of an
over temperature condition
Yes
Query Over
Temperature
Protection Tripped
[:]SENSe[<channel>]:TEMPerature:PROTection:TRI
Pped? Query temperature protection
tripped N/A
Set AC Fail
Response [:]SENSe[<channel>]:VOLTage:AC:PROTection:LATC
h <on-off-state> Select if output is latched off or
auto recovers in the case of an AC
Fail
Yes
Query AC Fail
Protection Tripped [:]SENSe[<channel>]:VOLTage:AC:PROTection:TRIP
ped? Query AC protection circuit
tripped N/A
Table C-12User Lines
Function SCPI Command Description Query
Select polarity of
Auxiliary Lines [:]OUTPut[<channel>]:AUXiliary<A|B>:POLarity
{HIGH|LOW} Configure the polarity of the
auxiliary line Yes
Select Source of
Auxiliary Line State [:]OUTPut[<channel>]:AUXiliary<A|B>:SOURce
<aux_line_mnemonic> Configure the auxiliary line Yes
Query state of
Auxiliary Line [:]OUTPut[<channel>]:AUXiliary<A|B>:STATe? Query the state of the auxiliary
line N/A
TM-XDOP-01XN.book Page 27 Monday, July 17, 2006 11:19 AM