Current Sharing

Overview

Current Share Configuration

Setup

Current

Sharing

Network

Units are programmed in a mode such that it is already in current sharing mode on power up. This feature is not user-modifiable. Please contact the manufacturer for assistance if you wish to change this.

Most configurable settings available on a master 6kW unit are disabled on the slave units for protection. All the queries are still available.

To set up multiple supplies for current share operation, follow these steps:

1.Power down the units. Connect the CAN ports of all paralleled units as explained in “CANbus Setup”.

2.Make load connections. It is recommended to keep load cables the same length if possible. See Figure 3.1.

3.Power up the master.

4.Power up the slaves one at a time.

5.Set the voltage and current on the master, then enable the output.