Specifications and Characteristics
AC Line Input Specifications
AC Line Input Specifications
The input to the power supply requires the following specifications.
AC Line Input
Voltage
Operating
Ranges
Table A.5AC Line Input Specifications
Operating Range |
|
nominal 208Vrms (Standard) | 190 to 242 Vac 3 φ (3 wire + safety ground) |
nominal 400Vrms (with | 342 to 500 Vac 3 φ (3 wire + safety ground) |
Frequency Range | 47 to 63 Hz |
|
|
Maximum Peak | 35 Arms |
|
|
Minimum Power Factor1 |
|
nominal 208Vrms (Standard) | 0.95 |
nominal 400Vrms (with | 0.9 |
Operating Current |
|
nominal 208Vrms (Standard) |
|
Maximum2 | 24 A |
Typical3 | 20 A |
Operating Current |
|
nominal 400Vrms (with |
|
Maximum4 | 13 A |
Typical5 | 11 A |
1.At nominal input voltage and maximum power
2.At 190Vac input voltage, 55°C ambient temperature and maximum power
3.At 208Vac input voltage, 25°C ambient temperature and maximum power
4.At 342Vac input voltage, 50°C ambient temperature and maximum power
5.At 400Vac input voltage, 25°C ambient temperature and maximum power
26 | Operating Manual for XDC Series Slave Power Supply |