TM-XDSL-01XN.book Page 25 Tuesday, November 5, 2002 3:22 PM

Specifications and Characteristics

Electrical Specifications—Summary

Table A.3Specifications for 80V to 600V Models

Models

80–75

100–60

150–40

300–20

600–10

 

 

 

 

 

 

Output Ratings:

 

 

 

 

 

Output Voltage 1

0–80 V

0–100 V

0–150 V

0–300 V

0–600 V

Output Current 2

0–75 A

0–60 A

0–40 A

0–20 A

0–10 A

Output Power

6000 W

6000 W

6000 W

6000 W

6000 W

 

 

 

 

 

 

Line Regulation: 3

 

 

 

 

 

Voltage (0.01% of Vmax)

8 mV

10 mV

15 mV

30 mV

60 mV

Current (0.05% of Imax)

37.5 mA

30 mA

20 mA

10 mA

5 mA

 

 

 

 

 

 

Load Regulation: 4

 

 

 

 

 

Voltage (0.05% of Vmax + 5 mV)

45 mV

55 mV

80 mV

155 mV

305 mV

Current (0.1% of Imax + 20 mA)

95 mA

80 mA

60 mA

40 mA

30 mA

 

 

 

 

 

 

Output Noise (0–20 MHz):

 

 

 

 

 

Voltage (p–p)

100 mV

100 mV

150 mV

250 mV

350 mV

 

 

 

 

 

 

Output Ripple (rms):

 

 

 

 

 

Voltage

15 mV

20 mV

20 mV

30 mV

80 mV

Current 5

320 mA

230 mA

120 mA

50 mA

25 mA

OVP Adjustment Range:

 

 

 

 

 

(0% to 110% of Vmax)

0–88 V

0–110 V

0–165 V

0–330 V

0–660 V

 

 

 

 

 

 

Efficiency: 6

0.89

0.90

0.90

0.91

0.91

1.Minimum output voltage is <0.3% of rated voltage at zero output setting.

2.Minimum output current is <0.2% of rated current at zero output setting when measured with rated load resistance.

3.For input voltage variation over the AC input voltage range, with constant rated load.

4.For 0–100% load variation, with constant nominal line voltage.

5.Current mode noise is measured from 10% to 100% of rated output voltage, full current, unit in CC mode.

6.Typical efficiency at nominal input voltage and full output power.

Table A.4Drift Specifications for 80V to 600V Models

Models

80–75

100–60

150–40

300–20

600–10

 

 

 

 

 

 

Drift (30 minutes): 1

 

 

 

 

 

Voltage (0.04% of Vmax)

32 mV

40 mV

60 mV

120 mV

240 mV

Current (0.6% of Imax)

450 mA

360 mA

240 mA

120 mA

60 mA

 

 

 

 

 

 

Drift (8 hours): 2

 

 

 

 

 

Voltage (0.02% of Vmax)

16 mV

20 mV

30 mV

60 mV

120 mV

Current (0.04% of Imax)

30 mA

24 mA

16 mA

8 mA

4 mA

 

 

 

 

 

 

Temperature Coefficient: 3

 

 

 

 

 

Voltage (0.04% of Vmax/°C)

32 mV

40 mV

60 mV

120 mV

240 mV

Current (0.06% of Imax/°C)

45 mA

36 mA

24 mA

12 mA

6 mA

 

 

 

 

 

 

1.Maximum drift over 30 minutes with constant line, load, and temperature, after power on.

2.Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.

3.Change in output per °C change in ambient temperature, with constant line and load.