Specifications and Characteristics

Output Performance Specifications

Time Delay From Output Enable Until Output Stable

2 s maximum

(Within regulation envelope)

Output Hold-Up Time – Power Off

Minimum 4 ms (at full load)

Output Hold-Up Time – Source Interruption

Minimum 4 ms with output deviation less than 5% of maximum output voltage after source interruption.

Transient Response Time1

Time to recover within 0.75% of rated output of previous level after step change in load current between 50% and 100%.

Mode

Time

 

 

Voltage Mode

3 ms stand alone unit1

1. 96 ms typical in current sharing configuration

Mode Crossover

Maximum deviation as a percentage of rated output voltage.

CV – CC Overshoot 1%

Peak–Peak and RMS Noise Bandwidth Limits

The frequency range for Peak to Peak measurements is 10 Hz–20 MHz.

The frequency range for RMS measurements is 10 Hz–100 kHz.

Maximum Remote Sense Line Drop Compensation

Minimum 3.8 V for each line, 5 V typical

Isolation

AC Input to Output

1350 Vac

AC Input to Chassis

1350 Vac

Output to Chassis

600 Vac

1.Time for the output voltage to recover within 0.75% of rated output of its previous level after a step change in load current of up to 50% - 100% and 100% to 50% of rated output