TM-XDSL-01XN.book Page 28 Tuesday, November 5, 2002 3:22 PM

Specifications and Characteristics

Output Performance Specifications

Typical Programming Resolution

Remote Digital Interface

Voltage

0.002% of Vmax

Current

0.002% of Imax

Power

0.05% of Pmax

Over Voltage Protection

0.002% of Vmax

 

 

Typical Measurement Resolution

Remote Digital Interface

Voltage

0.002% of Vmax

Current

0.002% of Imax

Power

0.05% of Pmax

 

 

Programming Accuracy1

Remote Digital Interface

Voltage Programming

0.1% of Vmax

Current Programming

0.5% of Imax

Power Programming

0.5% of Pmax

Over voltage

0.1% of Vmax

Programming

 

 

 

Readback Accuracy

Remote Digital Interface

Voltage Readback

0.15% of Vmax

Current Readback

0.5% of Imax

Power Readback

0.5% of Pmax

 

 

30 Minute Drift2

Voltage

0.04% of Vmax

 

 

Current

0.6% of Imax

 

 

Power

1% of Pmax

 

 

1.Accuracy specifications apply for settings in range of 1% to 100% of rated output

2.At 25°C ±5°C, with full power load

28

Operating Manual for XDC Series Slave Power Supply

Page 30
Image 30