1.Front output current limited to 30 A maximum.

2.For input voltage variation over the AC input voltage range, with constant rated load.

3.For 0 to 100% load variation, with constant nominal line voltage (rear output only).

4.Current mode noise is measured from 10% to 100% of rated output voltage, full current, resistive load.

5.Maximum drift over 60 minutes with constant line, load, and temperature, after power on.

6.Maximum drift over 8 hours with constant line, load, and temperature, after 60-minute warm-up.

7.Change in output per ° C change in ambient temperature, with constant line and load.

8.Typical efficiency is measured at 120 V and full output power.

Additional Specifications

Rise Time (No load, full load)

50 ms

 

 

Fall Time (Full load)

50 ms

 

 

Fall Time (No load)

400 ms

 

 

Voltage Mode Transient Response

1 ms

 

 

Time delay from power on until output stable

3 s maximum

 

 

Input Conditions

Rated AC Input Voltage

100/120/200/230/240 Vac, universal input

 

 

Maximum AC Input Power

700 W

 

 

Operational AC Input Voltage Range

85 to 264 Vac; power factor corrected

 

 

Maximum Input Current

7 A maximum at 100 Vac, 6 A maximum at

 

120 Vac, 3 A maximum at 220 Vac

 

 

Input Frequency Range

47 to 63 Hz

 

 

Power Factor

0.98 minimum for full load at nominal

 

voltage

 

 

Input Harmonic Distortion

Current harmonics meet IEC 1000-3-2

 

 

Release A