Options

Section 4. Remote Operation

Readback and Status Indicators

Remote See Table 4.1 for a summary of the options available to you for programming output Programming voltage and current limit using an analog source.

Options

Table 4.1 Remote Programming Options

Control of...

Programming Scale

Output voltage

0-10 V voltage sources

 

 

Current limit

0-10 V voltage sources

 

 

Programming Output Voltage with a 0-10 Vdc Voltage Source

Programming Output Current with

a0-10 Vdc Voltage Source

1.Connect J210 pin 6 (remote voltage program select) to J210 pin 8 (auxiliary ground).

2.Connect the control voltage source between pin 14 (voltage program) and pin 13 (program return).

3.Vary the external voltage from 0-10 Vdc to cause the power supply output to vary from 0-100% of rated output voltage.

1.Connect J210 pin 7 (remote current program select) to J210 pin 8 (auxiliary ground).

2.Connect the control voltage source between J210 pin 5 (current program, positive) and pin 8 (program return).

3.Vary the external voltage from 0-10 Vdc to cause the power supply current limit to vary from 0-100% of rated output.

Readback and Status Indicators

Voltage and

Current

Readback

Voltage Readback Connect a voltage monitoring device between J210 connector pin 15 (voltage readback - positive) and pin 13 (program return - negative).

Range: 0-10 V = 0-100% full rated voltage output of power supply

Current Readback Connect a voltage monitoring device between J210 connector pin 12 (current readback - positive) and pin 13 (program return - negative).

Range: 0-10 V = 0-100% full rated current output of power supply

50

Operating Manual for XPD Series Power Supply