Xantrex Technology XPD 18-30 Shipped Configuration Local Control Mode, OVP” on page 38 , for the

Models: XPD 18-30 XPD 33-16 XPD 120-4.5 XPD 7.5-67 XPD 60-9

1 56
Download 56 pages 43.26 Kb
Page 39
Image 39
Setting the

Setting the

Supply to

Operate in CI

Mode

Automatic

Mode

Crossover

Section 3. Local Operation

Shipped Configuration (Local Control Mode)

4.Disconnect the shorting lead from the output terminals. The power supply will now automatically switch into current limiting mode (current regulation) as soon as the preset current level is reached.

To operate the supply in CI mode:

1.Set the current limit as described above.

2.Set the voltage control fully clockwise or to the compliance voltage of the circuit.

As soon as the supply starts operating in current mode, the red current mode LED will turn on.

The automatic crossover system allows the power supply to automatically switch operating modes in response to changing load requirements. For example, if the load current attempts to increase above the setting of the current adjust control, the unit will switch automatically from Constant Voltage to Constant Current mode. If you lower the load requirements, the supply will automatically return to Constant Voltage mode.

Shipped Configuration (Local Control Mode)

The factory ships units already configured for local control (front panel) operation. See Table for a summary of this configuration.

Table 3.1 Shipped Configuration (Local Control Mode)

Local Control Configuration

Additional References

Use the front panel controls to adjust

See Section for front panel operation.

output voltage and current limit

See Section 4, page 49, for remote

settings.

analog programming procedures.

 

 

The OVP set point is adjusted at the

See “Using Over Voltage Protection

front panel to over 110% of rated

(OVP)” on page 38, for the

output voltage.

adjustment procedure.

 

 

Release A

37

Page 39
Image 39
Xantrex Technology XPD 18-30, XPD 60-9 manual Shipped Configuration Local Control Mode, See “Using Over Voltage Protection