Xerox D63-069-00 manual XES014I IDA XFC Running in Test Mode, XES015I no Printers Defined

Models: D63-069-00

1 72
Download 72 pages 62.87 Kb
Page 39
Image 39

XES014I IDA XFC RUNNING IN TEST MODE

Description

The product is running in TEST MODE, where only one printer can

 

be defined.

Severity

Information only message.

Action

Operation of one ICDS printer is possible without the idaXFC KEY

 

PROFILE statement (i.e. TEST MODE). If additional printers are re-

 

quired to be tested, obtain a product key from the product distributor.

XES015I NO PRINTERS DEFINED

Description

An operator operation has been attempted when no printers are de-

 

fined in the idaXFC profile.

Severity

No action will be performed (printing is not possible).

Action

Respecify the idaXFC profile to reference one or more printers.

XES016I IDA XFC LICENSED FOR nnnn PRINTERS

Description

Operation of the product has terminated as the number of licensed

 

printers has been exceeded.

Severity

Processing for the named subsystem is terminate.

Action

A maximum of stated number of printers may be defined for print op-

 

eration to all instances of IDAXFC operational on the same system

 

image. Support of additional printers will require use of another prod-

 

uct key.

XES017I nnnn PRINTERS DEFINED

Description

The idaXFC has located nnnn PRINTER definitions in the idaXFC

 

PROFILE.

Severity

Information only message.

Action

None.

XES019I INVALID DECIMAL NUMBER nnnnn

Description

A non-decimal numeric value has been specified in the IDAXFC pro-

 

file.

Severity

The value specified will not be used for the named printer.

Action

Correct the IDAXFC profile entry for the target printer.

XES020I OUT OF RANGE nnnnn

Description

An IDAXFC profile value contains a value that is outside of the ac-

 

ceptable range.

Severity

The value specified will not be used for the named printer.

Action

Correct the IDAXFC profile entry for the target printer.

A-4 ida XFC Installation Guide

Page 39
Image 39
Xerox D63-069-00 manual XES014I IDA XFC Running in Test Mode, XES015I no Printers Defined