fuse for the appliance must not exceed 5A.

DX100T only I

To adjust the over-run period turn the control

(T) clockwise to increase and anti-clockwise to decrease.

DX100H & DX100HP only J

Humidity operation is factory set at approx. 70% Relative Humidity (RH), but can be adjusted between 50% and 90% RH by control(H).

Time delay is factory set at approx. 20 mins, but can be adjusted by control (T).

Both controls are adjustable. Turn the controls clockwise to increase time or RH, and anti- clockwise to decrease.

DX100PIR only K

Adjust the overrun period with control (T). Turn screwdriver clockwise to increase and anti-clockwise to decrease.

All fans

If wiring from above cut out the cable entry slot marked on top of the front cover.

Fit the front cover by aligning it square to the duct and pushing it onto the duct until the release catches snap into the slots on the front cover.

Using the fan

DX100 & DX100VTD only

Operate the fan using the on/off switch. Repeat to switch off.

DX100PC only

Operate the fan by pulling and releasing the cord. Repeat to switch off.

DX100T only

Operate the fan using the on/off switch. When the switch is turned off, the fan continues to operate for the adjustable time delay.

DX100H only

Manual mode: use the on/off switch. When you switch off, the fan goes into automatic mode after the time delay (light indicates when fan is operating in manual mode).

Automatic mode: fan operates when relative humidity rises and turns off again when humidity drops.

DX100PIR only

The sensor detects movement in the room and activates the fan. When movement is sensed, the fan will run for a pre-set overrun period and any further movement sensed will re-start the sequence. This ensures that the room is only ventilated during and immediately after use. When the fan is first installed there will be a stabilising period of approximately five minutes. During this time the fan will run for up to two minutes.

Cleaning (recommended once a month)

A QUALIFIED ELECTRICIAN MUST CARRY OUT ALL CLEANING.

1.Before cleaning, isolate the fan completely from the mains supply.

2.Remove the front cover by pressing the release catches located on the sides at the unit with a 3mm screwdriver, whilst pulling the front cover forward L

3.To clean the front cover, either wipe it with a damp, lint free cloth or wash it in warm soapy water. Thoroughly dry the front cover and refit.

4.Do not immerse the fan in water or other liquids to clean any other parts of the fan.

5.Never use strong solvents to clean the fan.

6.Apart from cleaning, no other maintenance is required.

7

Page 7
Image 7
Xpelair DX100HP manual Fuse for the appliance must not exceed 5A, Using the fan, Cleaning recommended once a month