70 En
Troubleshooting

AUTO SETUP

Before AUTO SETUP

During AUTO SETUP

Error message Cause Remedy See
page
Connect MIC! Optimizer microphone is not connected. Connect the supplied optimizer microphone
to the OPTIMIZER MIC jack on the front
panel.
24
Unplug HP! Headphones are connected. Unplug the headphones.
Error message Cause Remedy See
page
E-1:NO FRONT SP Front L/R channel signals are not detected. Check the front L/R speaker connections. 11
E-2:NO SUR.SP A sur round channel signal is not detected. Check the surround speaker connections. 11
E-3:SBR->SBL Only a right surround back channel signal is
detected.
Connect the surround back speaker to the
LEFT SURROUND BACK SPEAKERS
terminal if you only have one surround
back speaker.
11
E-4:NOISY Background noise is too loud. Try running “AUTO SETUP” in a quiet
environment.
Turn off noisy electric equipment like air
conditioners or move them away from the
optimizer microphone.
E-5:CHECK SUR. Surround back speakers are connected,
though surround L/R speakers are not.
Connect surround speakers when you use
surround back speakers.
11
E-6:NO MIC The optimizer microphone was unplugged
during the “AUTO SETUP” procedure.
Connect the supplied optimizer microphone
to OPTIMIZER MIC jack on the front
panel.
24
E-7:NO SIGNAL The o ptimizer microphone does not detect
test tones.
Check the microphone setting. 24
Check the speaker connections and
placement.
10, 11,
24
E-8:USER CANCEL The “AUTO SETUP” procedure was
cancelled due to user activity.
Run “AUTO SETUP” again. 24
E-9:INTERNAL ERROR An internal error occurred. Run “AUTO SETUP” again. 24
01EN_DSP-AX563_B.book Page 70 Friday, February 1, 2008 11:08 AM