SOUND FIELD PROGRAM PARAMETER EDITING

Changing Parameter Settings

You can enjoy good quality sound with the factory-set parameters. Although you do not have to change the initial settings, you can change some of the parameters to better suit the input source or your listening room.

3

10KEY DSP

HALL 1

HALL 2

CHURCH

JAZZ CLUB

 

 

1

2

3

4

 

 

ROCK

ENTER-

MUSIC

TV

 

 

CONCERT5

TAINMENT6

VIDEO7

THEATER8

 

 

EX/ES

MOVIE

MOVIE

/DTS

 

 

 

THEATER 1

THEATER 2

SUR.

SELECT

 

 

 

9

10

11

12

 

 

CHP/INDEX

 

0

+10

+100

 

 

 

A/B/C/D/E PRESET

 

 

 

 

 

TV INPUT

 

MUTE

 

 

4

TV VOL

 

CH

 

VOLUME

 

 

TV MUTE

 

STEREO

 

 

 

 

DISC

EFFECT

 

 

 

 

 

 

PARAMETER

1

2

ON SCREEN

LEVEL

 

 

 

 

 

 

 

SET MENU

SLEEP

TEST

 

 

 

5

 

 

 

 

 

 

1 Set PARAMETER/SET

PARAMETER

MENU to PARAMETER.

SET MENU

 

2 Turn on the video monitor

ON SCREEN

and press ON SCREEN

 

repeatedly to select the

 

full display mode.

 

3 Select a DSP program you want to adjust.

10KEY DSP

HALL 1

HALL 2

CHURCH

JAZZ CLUB

 

1

2

3

4

 

ROCK

ENTER-

MUSIC

TV

 

CONCERT

TAINMENT

VIDEO

THEATER

 

5

6

7

8

 

MOVIE

MOVIE

/DTS

 

 

THEATER 1

THEATER 2

SUR.

SELECT

 

9

10

11

12

 

 

0

+10

+100

Program No. Program name

P05 ROCK CONCERT

 

 

 

The

Roxy

Theatre

Cursor

 

 

DSP

LEVEL ………… 0dB

 

≥ I N I T . D L Y … … … … 1

5 m s

 

 

 

 

R O O M S I Z E … … … … 1 . 0

 

 

 

L I V E N E S S … … … … … … … 5

 

 

 

R E V . T I M E … … … … 1 . 6 s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameters

Parameter valves

Example of the parameter setting display

4 Press k / n to select the parameter.

5 Press –/+ to change the parameter value.

When you set the parameter to a value other than the factory- set value, an asterisk mark (*) appears by the parameter name on the video monitor.

6 Repeat steps 3 to 5 above as necessary to change other program parameters.

Notes

The available parameters may be displayed on more than one OSD page for some of the programs. To scroll through pages, press k/ n.

You cannot change parameter values when “14 MEMORY GUARD” on the SET MENU is set to ON. If you want to change the parameter values, set “14 MEMORY GUARD” to OFF (see page 66).

Memory back-up

The memory back-up circuit prevents the stored data from being lost even if this unit is set in the standby mode, the power cord is disconnected from the AC outlet, or the power supply is temporarily cut due to power failure. However, if the power is cut for more than one week, the parameter value you edited will return to the factory setting. If so, edit the parameter value again.

Resetting a Parameter to the

Factory-set Value

To reset some of the parameters

to the factory-set values

Select the parameter you want to reset. Then press and hold –/+ until the value temporarily stops at the factory- set value. The asterisk mark (*) by the parameter name disappears on the video monitor.

To reset all of the parameters to the factory-set values

Use “9 PARAM. INI” on the SET MENU to reset all of the parameter values of all DSP programs within the selected group to the factory-set values (see page 63). This operation resets all of the parameter values of all DSP programs within that group to the factory-set values.

70