86
Appendix
Troubleshooting
Pitch or intervals are wrong.
• Is the Master Tune parameter in the Utility mode set at a value other than “0”? (Ref. #185)
• Is the Note Shift parameter in the Utility mode set at a value other than “0”? (Ref. #31)
• When the voice produces a wrong pitch, is the appropriate tuning system selected from Micro Tuning parameter in the
Voice Edit mode? (Ref. #5)
• When the voice produces a wrong pitch, is the LFO Pitch Modulation Depth in the Voice Edit mode set too high?
(Ref. #148)
• When the multi produces a wrong pitch, is the Note Shift parameter of each part set at a value other than “0”? (Ref. #31)
• When the multi produces a wrong pitch, is the Detune parameter of each part set at a value other than “0”? (Ref. #127)
Only one note sounds at a time.
• Is the Mono/Poly parameter in the Voice mode set to “mono”? (Ref. #3)
No effect is applied.
• Is the EFFECT BYPASS parameters set to “bypass”? (Ref. #15)
• Have any or all of the elements’ Effect Output parameter been set to “thru”? (Ref. #163)
• Have any or all of the effect types been set to “thru” or “off” (in the Effect Edit display)?
(Ref. #165-#167, #173)
MIDI bulk data reception won’t work properly.
• Is the Receive Bulk parameter set to “protect” in the Utility mode? (Ref. #158)
Plug-in board does not work.
• Has the Multi-part Plug-in board been installed to PLG1? (The Multi-part Plug-in board should be installed to PLG2.)
(Page 82)